A large neighborhood with one access road, over a pond spillway. The culvert was close to failing, workspace was limited and something had to be done. Our system can access the pipe with less than 50 square feet at the pipe and 1,200 square feet on the right of way. When completed our structural liner effectively replaces the original host pipe with a 75 year design life and 25 year manufacturer's warranty!
A 36" pipe with a failed invert. We repaired the invert and applied a ½" structural liner for significantly less than the cost of a jack and bore replacement.
Rehabilitation is accomplished using a spray applied combination of products:
Both materials will be applied robotically on round culverts and manually on arched culverts. Application is monolithic with no layering.
Complete application comes without negative change to the hydraulics. The loss to the radius is minimal, often under 1". The Manning's n Value is 0.0095 and Average C Coefficient is 149.
This liner solution is especially good for large culverts due to the lighter application thickness.
All culvert types, 36" and larger (haven't found one too big yet)
Manufacturer's Brochures: